/* conv-vfx.css — process-bound colour and motion for the Conventional HMI sheets (js/conv/vfx.js,
   PRD-CONV-LIVING-PLANT §4). A line's BODY colour is its condition; the moving dashes keep the medium colour, so the
   medium stays readable; every state also has a dash pattern, so the sheet reads without colour.
   Modes on .hmi-frame[data-vfx-mode]: state (default) | thermal | medium | flat. Tokens only; both themes. */
:root:not([data-theme="dark"]) {
  --vfx-run: #1a7f37; --vfx-warn: #8a5300; --vfx-alarm: #b42318; --vfx-stby: #3f6475; --vfx-stop: #6b7280; --vfx-na: #9aa3ad;
  --vfx-bar-bg: #ffffff; --vfx-bar-line: rgba(15, 23, 42, .14); --vfx-bar-text: #1b2430; --vfx-bar-mute: #4b5563; --vfx-acc: #7a4800;
}
[data-theme="dark"] {
  --vfx-run: #3fb950; --vfx-warn: #e8b563; --vfx-alarm: #f85149; --vfx-stby: #7fa6b8; --vfx-stop: #8b93a1; --vfx-na: #5b6370;
  --vfx-bar-bg: #121316; --vfx-bar-line: rgba(255, 255, 255, .12); --vfx-bar-text: #e8edf5; --vfx-bar-mute: #9aa4b2; --vfx-acc: #e8b563;
}

/* refrigerant and oil media of the equipment internal drawings (js/conv/internals/*.js, PRD-CONV-EQUIPMENT-TRUTH E2):
   the medium colour of a line (Medium view, flow dashes, arrows); the State view still paints the body by condition */
:root:not([data-theme="dark"]) { --hmi-m-ref-lpv: #1f6f66; --hmi-m-ref-hpv: #8f3f22; --hmi-m-ref-liq: #6e5a14; --hmi-m-ref-flash: #2f5f78; --hmi-m-oil: #5f4630; }
[data-theme="dark"] { --hmi-m-ref-lpv: #7cc4b8; --hmi-m-ref-hpv: #d98a6a; --hmi-m-ref-liq: #d0b866; --hmi-m-ref-flash: #9ec3d9; --hmi-m-oil: #b39274; }
.hmi-svg .m-ref_lpv { stroke: var(--hmi-m-ref-lpv); } .hmi-svg .m-ref_hpv { stroke: var(--hmi-m-ref-hpv); } .hmi-svg .m-ref_liq { stroke: var(--hmi-m-ref-liq); }
.hmi-svg .m-ref_flash { stroke: var(--hmi-m-ref-flash); } .hmi-svg .m-oil { stroke: var(--hmi-m-oil); }
.hmi-svg .hmi-arrow.m-ref_lpv { color: var(--hmi-m-ref-lpv); } .hmi-svg .hmi-arrow.m-ref_hpv { color: var(--hmi-m-ref-hpv); } .hmi-svg .hmi-arrow.m-ref_liq { color: var(--hmi-m-ref-liq); }
.hmi-svg .hmi-arrow.m-ref_flash { color: var(--hmi-m-ref-flash); } .hmi-svg .hmi-arrow.m-oil { color: var(--hmi-m-oil); }

/* ── state mode: the pipe body carries the condition ─────────────────────────────────────────────── */
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="running"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-run); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="warning"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-warn); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="alarm"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-alarm); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="stopped"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-stop); }
/* standby: charged and ready, no water moving — a solid line in the standby colour, never a dashed "stopped" one */
.hmi-frame .hmi-svg .hmi-edge[data-vstate="standby"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke-dasharray: none; }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="standby"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-stby); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="mismatch"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-warn); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-edge[data-vstate="unavailable"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-na); }
/* flat (ISA-101 practice): grey when normal, colour only on abnormal */
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-edge[data-vstate]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-stop); }
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-edge[data-vstate="warning"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi),
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-edge[data-vstate="mismatch"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-warn); }
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-edge[data-vstate="alarm"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-alarm); }
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-flow[data-vstate] { stroke: var(--vfx-stop); }
/* thermal: the body is the water temperature; a line with no temperature point, or with no flow, stays neutral */
.hmi-frame[data-vfx-mode="thermal"] .hmi-svg .hmi-edge[data-vstate]:not([data-vstate="stopped"]):not([data-vstate="unavailable"]):not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-t, var(--vfx-na)); }
.hmi-frame[data-vfx-mode="thermal"] .hmi-svg .hmi-edge[data-vstate="stopped"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-stop); }
.hmi-frame[data-vfx-mode="thermal"] .hmi-svg .hmi-edge[data-vstate="unavailable"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke: var(--vfx-na); }
.hmi-frame[data-vfx-mode="thermal"] .hmi-svg .hmi-flow[data-vstate] { stroke: var(--hmi-text, #e8edf5); opacity: .75; }

/* ── the second signal: pattern, in every mode ───────────────────────────────────────────────────── */
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-edge[data-vstate="warning"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke-dasharray: 12 3; }
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-edge[data-vstate="alarm"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke-dasharray: 7 2 1.5 2; }
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-edge[data-vstate="mismatch"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke-dasharray: 2 3; }
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-edge[data-vstate="unavailable"]:not(.hmi-flow):not(.hmi-edge-shadow):not(.hmi-edge-hi) { stroke-dasharray: 1 4; }

/* ── flow: longer dashes than the sheet's dots; the period comes from the flow (inline animation-duration) ── */
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-flow[data-vstate] { stroke-dasharray: 5 11; stroke-width: 1.6; stroke-linecap: round; }
.hmi-frame[data-vfx-mode] .hmi-svg .hmi-flow[data-vstate]:not([data-vmove]) { display: none; }

/* ── symbols: body outline by condition ──────────────────────────────────────────────────────────── */
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="running"] .b { stroke: var(--vfx-run); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="standby"] .b { stroke: var(--vfx-stby); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="warning"] .b,
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-node[data-vstate="warning"] .b { stroke: var(--vfx-warn); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="alarm"] .b,
.hmi-frame[data-vfx-mode="flat"] .hmi-svg .hmi-node[data-vstate="alarm"] .b { stroke: var(--vfx-alarm); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="mismatch"] .b { stroke: var(--vfx-warn); stroke-dasharray: 2 2; }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="stopped"] .b { stroke: var(--vfx-stop); }

/* pump rotor: a broken ring inside the casing; it turns only while the pump runs, at its speed */
.hmi-svg .vfx-rotor { fill: none; stroke: currentColor; stroke-width: 1.2; stroke-dasharray: 4 5.2; opacity: .85; pointer-events: none;
  transform-box: fill-box; transform-origin: center; color: var(--vfx-stop); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="running"] .vfx-rotor { color: var(--vfx-run); }
.hmi-frame[data-vfx-mode="state"] .hmi-svg .hmi-node[data-vstate="warning"] .vfx-rotor { color: var(--vfx-warn); }
@media (prefers-reduced-motion: no-preference) {
  .hmi-svg .vfx-rotor[data-spin] { animation: vfx-turn 1s linear infinite; }
}
@keyframes vfx-turn { to { transform: rotate(360deg); } }
.hmi-depth.is-offscreen .vfx-rotor { animation-play-state: paused !important; }

/* ── view bar + legend ───────────────────────────────────────────────────────────────────────────── */
.vfx-bar { display: flex; flex-wrap: wrap; align-items: center; gap: 4px 12px; padding: 4px 12px; background: var(--vfx-bar-bg);
  border-bottom: 1px solid var(--vfx-bar-line); color: var(--vfx-bar-text); font: 400 11px/1.3 'IBM Plex Sans', system-ui, sans-serif; }
.vfx-bar-k { font: 600 11px/1 'JetBrains Mono', ui-monospace, monospace; letter-spacing: .05em; text-transform: uppercase; color: var(--vfx-bar-mute); }
.vfx-modes { display: inline-flex; }
.vfx-mode { padding: 4px 8px; border: 1px solid var(--vfx-bar-line); background: transparent; color: var(--vfx-bar-mute); font: inherit; cursor: pointer; }
.vfx-mode + .vfx-mode { border-left: 0; }
.vfx-mode:first-child { border-radius: 3px 0 0 3px; } .vfx-mode:last-child { border-radius: 0 3px 3px 0; }
.vfx-mode[aria-pressed="true"] { color: var(--vfx-bar-text); border-color: var(--vfx-acc); box-shadow: inset 0 -2px 0 var(--vfx-acc); }
.vfx-mode:focus-visible { outline: 2px solid var(--vfx-acc); outline-offset: 1px; }
@media (pointer: coarse) { .vfx-mode { min-height: 44px; padding: 4px 12px; } }
.vfx-legend { display: inline-flex; flex-wrap: wrap; gap: 4px 12px; color: var(--vfx-bar-mute); }
.vfx-lg { display: inline-flex; align-items: center; gap: 4px; white-space: nowrap; }
.vfx-lg-line { display: inline-block; width: 26px; height: 2px; background: var(--vfx-stop); }
.vfx-lg-line[data-vstate="running"] { background: var(--vfx-run); }
.vfx-lg-line[data-vstate="warning"] { background: repeating-linear-gradient(90deg, var(--vfx-warn) 0px 12px, transparent 12px 15px); }
.vfx-lg-line[data-vstate="alarm"] { background: repeating-linear-gradient(90deg, var(--vfx-alarm) 0px 7px, transparent 7px 9px, var(--vfx-alarm) 9px 10.5px, transparent 10.5px 12.5px); }
.vfx-lg-line[data-vstate="standby"] { background: var(--vfx-stby); }
.vfx-lg-line[data-vstate="stopped"] { background: repeating-linear-gradient(90deg, var(--vfx-stop) 0px 6px, transparent 6px 10px); }
.vfx-lg-line[data-vstate="mismatch"] { background: repeating-linear-gradient(90deg, var(--vfx-warn) 0px 2px, transparent 2px 5px); }
.vfx-lg-line[data-vstate="unavailable"] { background: repeating-linear-gradient(90deg, var(--vfx-na) 0px 1px, transparent 1px 5px); }
.vfx-ramp { display: inline-block; width: 46px; height: 6px; border-radius: 1px; background: linear-gradient(90deg, rgb(59, 130, 246), rgb(232, 181, 99), rgb(239, 68, 68)); }
.vfx-lg-ramp { display: none; }
.vfx-legend[data-mode="thermal"] .vfx-lg:not(.vfx-lg-ramp) { display: none; }
.vfx-legend[data-mode="thermal"] .vfx-lg-ramp { display: inline-flex; }
.vfx-legend[data-mode="medium"] .vfx-lg { display: none; }
.vfx-legend[data-mode="flat"] .vfx-lg[data-vstate="running"], .vfx-legend[data-mode="flat"] .vfx-lg[data-vstate="standby"] { display: none; }

/* ── air section (js/conv/air-section.js) ────────────────────────────────────────────────────────────
   One schematic cut through a data-hall row. Colours arrive as --as-* from the model (temperature on the
   thermal ramp); motion exists only while the model publishes a duration, and never under reduced motion —
   the arrowheads stay, so direction is still readable. */
.air-sec { border: 1px solid var(--border, #31353F); border-radius: 4px; background: var(--bg-panel, #15171a); padding: 8px; }
.air-sec-head { display: flex; flex-wrap: wrap; align-items: baseline; gap: 4px 12px; margin-bottom: 4px; color: var(--txt-dim, #94a3b8); font: 400 11px/1.3 'IBM Plex Sans', system-ui, sans-serif; }
.air-sec-head b { font: 600 11px/1.3 'JetBrains Mono', ui-monospace, monospace; letter-spacing: .05em; text-transform: uppercase; color: var(--txt-main, #e2e8f0); }
.air-sec { display: flex; flex-direction: column; }
.air-sec > #air-sec-host { flex: 1 1 auto; min-height: 0; }
.as-scroll { height: 100%; overflow-x: auto; overscroll-behavior-x: contain; scrollbar-width: thin; }
.as-svg { display: block; width: 100%; min-width: 680px; max-height: 100%; height: auto; color: var(--txt-dim, #94a3b8); }
.as-svg .as-wall { fill: none; stroke: var(--txt-dim, #94a3b8); stroke-width: 1.4; }
.as-svg .as-ceil { fill: none; stroke: var(--txt-dim, #94a3b8); stroke-width: 1; stroke-dasharray: 6 4; }
.as-svg .as-box { fill: none; stroke: var(--txt-main, #e2e8f0); stroke-width: 1.2; }
.as-svg .as-coil { fill: none; stroke: var(--as-chws, var(--vfx-stop)); stroke-width: 1.4; }
.as-svg .as-fan-ring { fill: none; stroke: var(--txt-dim, #94a3b8); stroke-width: 1; }
.as-svg .as-fan { fill: var(--vfx-stop); transform-origin: 136px 186px; transform-box: view-box; }
.as-svg[data-fan] .as-fan { fill: var(--vfx-run); }
.as-svg .as-rack { fill: var(--as-rack, transparent); fill-opacity: .28; stroke: var(--txt-main, #e2e8f0); stroke-width: 1.2; }
.as-svg .as-rack-u { fill: none; stroke: var(--txt-dim, #94a3b8); stroke-width: .6; opacity: .6; }
.as-svg .as-line { fill: none; stroke-width: 1.6; stroke: var(--vfx-stop); stroke-dasharray: 6 4; }
.as-svg[data-air] .as-line { stroke-dasharray: none; }
.as-svg[data-air] .as-line.as-cold { stroke: var(--as-cold); }
.as-svg[data-air] .as-line.as-hot { stroke: var(--as-hot); }
.as-svg[data-air] .as-line.as-thr { stroke: inherit; }
.as-svg .as-line.as-chws, .as-svg .as-line.as-chwr { stroke-width: 2.4; }
.as-svg[data-chw] .as-line.as-chws { stroke: var(--as-chws); stroke-dasharray: none; }
.as-svg[data-chw] .as-line.as-chwr { stroke: var(--as-chwr); stroke-dasharray: none; }
.as-svg .as-g-cold { stop-color: var(--as-cold, var(--vfx-stop)); } .as-svg .as-g-hot { stop-color: var(--as-hot, var(--vfx-stop)); }
.as-svg .as-flow { display: none; fill: none; stroke: var(--bg-panel, #15171a); stroke-width: 1.6; stroke-dasharray: 2 14; pointer-events: none; }
.as-svg .as-flow.as-chws, .as-svg .as-flow.as-chwr { stroke-width: 2.4; }
.as-svg .as-name { fill: var(--txt-main, #e2e8f0); font: 600 11px 'IBM Plex Sans', system-ui, sans-serif; }
.as-svg .as-lbl { fill: var(--txt-dim, #94a3b8); font: 400 11px 'IBM Plex Sans', system-ui, sans-serif; }
.as-svg .as-val { fill: var(--txt-main, #e2e8f0); font: 600 11px 'JetBrains Mono', ui-monospace, monospace; }
.as-svg .as-val[data-basis-param] { cursor: pointer; }
.as-svg[data-vstate="warning"] [data-as="inlet"] { fill: var(--vfx-warn); }
.as-svg[data-vstate="alarm"] [data-as="inlet"] { fill: var(--vfx-alarm); }
@media (prefers-reduced-motion: no-preference) {
  .as-svg[data-air] .as-flow.as-cold, .as-svg[data-air] .as-flow.as-hot, .as-svg[data-air] .as-flow.as-thr { display: inline; animation: as-march var(--as-air-dur, 1s) linear infinite; }
  .as-svg[data-chw] .as-flow.as-chws, .as-svg[data-chw] .as-flow.as-chwr { display: inline; animation: as-march var(--as-chw-dur, 1s) linear infinite; }
  .as-svg[data-fan] .as-fan { animation: vfx-turn var(--as-fan-dur, 1s) linear infinite; }
}
@keyframes as-march { to { stroke-dashoffset: -16; } }

/* ── switching devices on the single-line (E-S-101, js/conv/epms-sim.js) ─────────────────────────────────
   The drawn contact IS the device position: open = the symbol's angled blade, closed = the blade turned onto the
   line (data-pos from the page's switching state). The blade travels in 180 ms; reduced motion snaps it. */
.hmi-svg .hmi-node[data-pos] .b { transform-box: fill-box; transform-origin: 100% 100%; }
.hmi-svg .hmi-node[data-pos="closed"] .b { transform: rotate(33deg); }
@media (prefers-reduced-motion: no-preference) {
  .hmi-svg .hmi-node[data-pos] .b { transition: transform 180ms cubic-bezier(.2, 0, 0, 1); }
}