Building Overview
Primary read: where is the alarm and where do I click next?
Click any floor to explore room layout — 72m × 48m × 4 levels — 13,824 m² total
PUE
1.30
Derived | Target ≤1.12
WUE
0.00
L/kWh · Dry-only
CUE
0.90
kgCO₂/kWh IT
IT Load
14.26
MW · Scenario A locked
GPUs
7,776
Blackwell
NVL72
108
Domains
Uptime
99.99
% YTD
Alarms
0
Active
Electrical
| TX-A/B | 5MVA Online |
| UPS-A/B | 4.5MW Online |
| Busway | 2×4,000A |
| GenSet | 4×2.5MW Standby |
Cooling
| TCS Sup | 35.2°C |
| TCS Ret | 44.8°C |
| CDUs | 36/48 fac · 9/12 hall |
| Chillers | 12/16 Run · design |
Network
| NVLink5 | All Up |
| IB XDR | 800G Online |
| OOB/BMC | Active |
Safety
| Fire/VESDA | Normal |
| EPO | Armed |
| Leak Detect | Clear |
Access
| Personnel | 3 Inside |
| Last Entry | 12:34 |
Primary read: where are the outliers — thermal, power, cooling margin?
PUE
1.30
Derived | basis ▾
IT
3,564
kW
GPU%
94
1,944
NVLink
100%
27dom
ΔT
9.6
°C
DLC
85%
3.03MW
Up
99.998
%
W/GPU
1050
avg
FP4
1400
EF
AI RackNetworkPassiveCDU (EoR)In-Rack CDU▲Hot▼Cold◆TTHT― OH Pipe
Rack Architecture
Primary read: how is an NVL72 built — and what is the current risk on the selected rack?
Specifications & detail panels
Cooling & Piping P&ID
Primary read: where is the heat going — and what is the cooling constraint right now?
Specifications & detail panels
Facility Electrical SLD
Primary read: what is energized, what is loaded, what is at risk of trip?
Specifications & detail panels
DH-01 Electrical SLD
Specifications & detail panels
DH-02 Electrical SLD
Specifications & detail panels
DH-03 Electrical SLD
Specifications & detail panels
DH-04 Electrical SLD
Specifications & detail panels
Network Fabric Topology
Primary read: what is the fabric health — congestion, packet loss, degraded redundancy?
Specifications & detail panels
Fire Detection & Suppression P&ID
Primary read: what is the current protection state — and what is bypassed?
Specifications & detail panels
BMS/DCIM Architecture
Primary read: is the monitoring system itself trustworthy?
Historian: Online· 1 yr hi-res + 5 yr daily
Notification: Online· email + SMS + push
Gateways: 16 / 16online
Alarms: 0 active·0 ack·0 cleared