Optus Australia Nationwide Outage — Routing Change Cascade (November 8, 2023)
Summary
Following a routine Singtel-network software upgrade, a large, unexpected flood of routing information exceeded preset safety limits on Optus routers, which self-isolated and cascaded into a roughly 14-hour nationwide outage of Optus mobile and internet for about 10 million Australians — disrupting triple-zero (000) emergency calls, hospitals, transport and payments.
- Users affected
- ~10 million Optus customers nationwide; triple-zero (000) calls affected
- Duration
- 8h 55m — Onset ~04:05 AEDT 8 Nov → ~88% of network restored by 13:00 AEDT.
- Financial
- Regulatory scrutiny; CEO resignation; customer compensation
- Scope
- Sev-1 national network core (routing)
- Site
- Optus national network core · Sydney, Australia
- Services down
- Optus mobile voice/data nationwide, Home internet, Triple-zero (000) emergency calling (partial), Transport/payment dependencies
How the defences failed
A routing change after a network-software upgrade cascaded into a nationwide outage (~9 h to ~88 % of the network restored, 12–13 h to full restoration) for ~10M Australians, disrupting triple-zero (000) — sub-scores ESTIMATED from public impact reporting, pending deep research.
All 12 impact metrics
| BGP route-announcement flood | ~940,000 announcements in one hour vs <3,000/hr normal (~300x) |
| Provider Edge routers self-disconnected | ~90 edge/PE routers |
| People affected | >10 million people and 400,000 businesses |
| Outage duration | ~12-13 hours (some media reported up to 14) |
| Restoration progress | ~11% by 11:30 AEDT; ~88% by 13:00 AEDT |
| Onset time | 8 Nov 2023, ~04:05 AEDT |
| Singtel market-value loss | >AU$2 billion (4.8% share-price drop) |
| Physical-world cascade | ~500 Melbourne train services cancelled; network shutdown 05:00-06:00 AEDT |
| Customer compensation | 200 GB extra data (post-paid); unlimited weekend data (prepaid, rest of 2023) |
| Emergency-services impact | Triple-Zero (000) calls failed (exact count not in retrievable record) |
| Competitor diversion (press, unverified) | TPG/Vodafone ~4x activity; Kogan Mobile +400% eSIM sales |
| Optus market position (press, unverified) | ~10 million customers, ~31% market share |
Sequence of events
- TRIGGER Scheduled software upgrade performed on a router at a North American node of Singtel's international peering network, the upstream infrastructure Optus's IP core depends on.Change owner
- TRIGGER The Singtel exchange upgrade caused one router to disconnect, initiating an abnormal BGP route-advertisement event toward Optus's AS4804.
- DETECTION Cloudflare telemetry for AS4804 registered the anomaly as a mass BGP spike — 'over 940,000 announcements in an hour from a node that normally makes less than 3,000 announcements per hour.'
- DETECTION Optus's Cisco PE routers registered the flood as incoming route updates crossed 'the pre-configured default threshold limits set by Cisco Systems.'
- MITIGATION Built-in threshold self-protection activated as designed: routers began tearing down BGP sessions to prevent CPU/memory exhaustion.
- CASCADE 'Approximately 90 edge provider routers disconnected as an automated protective measure against routing update overload' — a synchronized self-isolation across the PE fleet.
- CASCADE With ~90 PE routers withdrawn from BGP, Optus's IP core effectively vanished from the internet for its customers (network-layer 'de-energisation').
- IMPACT Nationwide loss of mobile and fixed service affecting 'more than 10 million people' and '400,000 businesses.'
- IMPACT Emergency Triple-Zero (000) calls failed for affected customers; exact count of failed calls not in retrievable record.
- IMPACT Physical-world cascade: Melbourne's train network experienced a shutdown from 05:00 to 06:00 and about 500 train services were cancelled; hospital phone lines and EFTPOS/payment terminals were disrupted.
- CASCADE Customers diverted to rivals: TPG/Vodafone reported a roughly four-fold activity increase and Kogan Mobile a ~400% rise in eSIM sales (press figures, not re-verified this session).Customer
- MITIGATION Optus publicly confirmed the outage was 'not due to a cyberattack,' focusing recovery on the routing fault.Communications lead
- RECOVERY Because tripped BGP sessions do not self-heal, engineers manually reconnected/rebooted affected routers (manual/on-site detail inferred from the recovery profile).Service recovery lead
- RECOVERY Partial restoration reached approximately 11% of the network.
- RECOVERY Restoration advanced to approximately 88% of the network.
- RESTORED Full service restored after approximately 12-13 hours (some media reported up to a 14-hour outage).
- IMPACT Singtel lost over AU$2 billion in value, a 4.8% share-price drop attributed to the outage.
- IMPACT Optus CEO Kelly Bayer Rosmarin resigned; a Senate public inquiry and an independent government (Bean) review were established.Crisis leadAuthority / investigator
Response by role
What each role did
Roles the sequence of events shows acting; every entry quotes its source line. Select a time to jump to it.
Role by role
Recorded actions / playbook actions per role. A role with 0 recorded actions does not appear in the sources.
No on-call engineer is named in the record; the routers detected the flood themselves — Meets the first alarm: on-shift technician or security in a facility, on-call engineer in a service.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
- FM-03Track the count of down PE sessions against time and report restored percentage to the commander every 30 minutesSRE incident mgmt
- FM-01Alarm Optus NOC on BGP announcement rate from Singtel peers against the 3,000 per hour baseline, instead of relying on Cloudflare telemetrySRE incident mgmt
- FM-02Alert the NOC when PE route counts pass a warning level well below the teardown threshold, so staff act before routers isolateSRE incident mgmt
- FM-04Run a continuous test call to 000 from a probe on the Optus network and page the NOC on the first failureSRE incident mgmt
- FM-05Give the Optus NOC advance notice of every Singtel change window and watch BGP counters through itChange management
Optus network operations staff running the IP core — not named — Technical lead who diagnoses and drives the fix; the subject-matter expert at the keyboard or the switchboard.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
No incident commander is named in the record — Owns every decision until formally relieved: site duty manager on scene, or the declared IC of a service incident.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
- FM-02Declare the incident, confirm no cyberattack, and set the first goal as getting the PE fleet back in BGPSRE incident mgmt
- FM-04Notify emergency services and the regulator at once that 000 is failing, so they can run alternate channelsITIL 4
- FM-05Call a joint Singtel and Optus bridge so the upstream change owner can stop and roll back the upgradeSRE incident mgmt
Singtel network staff who ran the router upgrade at a North American exchange — Authored or approved the change, deployment or configuration push that started the event.
On the record
- Performs a scheduled software upgrade on a Singtel peering router, the trigger of the BGP flood
Scheduled software upgrade performed on a router at a North American node
Playbook analyst guidance by failure mode, not a record of what happened
- FM-01Add inbound prefix filters and a route-count rate limit on the Singtel ingress toward AS4804 before any exchange upgradeCorrection of errors #2
- FM-02Set operator-tuned limits with warn-then-restart behaviour on every PE router rather than synchronized hard session teardownChange managementCorrection of errors #1
- FM-05Run Singtel and Optus changes through one joint staged rollout with a blast-radius review and a coordinated rollback planCorrection of errors #4
- FM-01Shut the affected Singtel peering session or apply a max-prefix cut at ingress when announcements spike far over baselineChange management
- FM-05Roll back the exchange upgrade on the node that disconnected and confirm announcements are back to normalChange management
Cisco Systems, maker of the PE routers and their default thresholds — Third party whose product, service or network sits in the failure path.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
- FM-02Advise operators in writing that Cisco default route-limit thresholds are not sized to their route counts and must be tunedChange managementLesson #2
Optus engineers who reconnected and rebooted the affected routers — Restores customer service: failover, workload moves, capacity, backlog drain.
On the record
- Reconnect and reboot the affected routers by hand because tripped BGP sessions do not self-heal
engineers manually reconnected/rebooted affected routers
Playbook analyst guidance by failure mode, not a record of what happened
- FM-03Pre-stage remote reboot and automated session recovery for PE routers so restoration needs no site visitsImprovement #5
- FM-03Reconnect and reboot routers in turn until the fleet is restored; the record shows 11% at 11:30 and 88% at 13:00ITIL 4
- FM-01Re-establish the peering session only after the filter is in place and the announcement rate is back near baselineITIL 4Improvement #2
- FM-02Clear the flood source first, then reconnect the PE routers in batches so they do not trip again on re-advertisementITIL 4
- FM-04Restore the 000 path first among customer services and run a welfare-check process for missed callsCorrection of errors #3
Optus public statements — spokesperson not named — Status page, customer notices, regulators and press; one voice, timed updates.
On the record
- States publicly that the outage was not a cyberattack and points recovery at the routing fault
Optus publicly confirmed the outage was 'not due to a cyberattack,'
Playbook analyst guidance by failure mode, not a record of what happened
Optus executive leadership, including CEO Kelly Bayer Rosmarin — Executive owner of business continuity: invokes plans, commits money, speaks to authorities.
On the record
Playbook analyst guidance by failure mode, not a record of what happened
- FM-05Agree in writing who owns a change on shared infrastructure, so accountability is not disputed afterwardsContributing factor #6
Senate public inquiry and the independent government (Bean) review — Regulator, investigator or court that establishes cause and obligations after the event.
On the record
- Government opens a Senate inquiry and the Bean review into the outage
a Senate public inquiry and an independent government (Bean) review were established
Playbook analyst guidance by failure mode, not a record of what happened
- FM-04Require Triple-Zero calling to stay available when the carrier's IP core is down, for example by camp-on to other networksImprovement #4
Optus mobile and fixed customers, hospitals, transport and payment users — The tenant or service user: their own redundancy, backups and continuity plan.
On the record
- Move to TPG/Vodafone and Kogan Mobile during the outage, per press figures
Customers diverted to rivals
Playbook analyst guidance by failure mode, not a record of what happened
Failure mode & effects analysis (FMEA)
Optus's national IP core and the upstream Singtel peering it depends on: the peering boundary that let a route flood through, the route-limit thresholds on Optus's ~90 Cisco Provider Edge routers, the manual recovery of tripped BGP sessions, Triple-Zero (000) emergency calling, and change management across the Singtel-Optus boundary. This dossier is press-sourced: only Wikipedia was re-fetched (citing Cloudflare telemetry and Optus's stated cause); the Bean review, Senate and ACMA findings were not retrievable, so no official finding is quoted. The upstream filtering gap and the manual, on-site recovery detail are the dossier's inferences from the mechanism, not verbatim findings, and Singtel reportedly disputed that its upgrade caused the outage (single-sourced, not re-verified). No corrective action has a status stated as done or committed by Optus or Singtel, so no revised score is claimed: every mode is residual risk.
- Caught only after impactD ≥ 8
- 5 of 5
- Actions that cut occurrenceO lowered
- 0
- Actions that cut detectionD lowered
- 0
- Actions that cut severityblast radius unchanged
- 0
FM-03 Tripped sessions do not re-establish on their own, and restoration proceeds by manual reconnection and rebootRecovery of tripped BGP sessions 8·6·8 384 —
- Function
- Bring the PE routers back into service quickly once the flood has passed
- Effect
- About 11% of the network restored by 11:30 AEDT and 88% by 13:00; full service after ~12-13 hours (some media report up to 14)
- Cause
- Standard max-prefix behaviour holds sessions down until an operator re-enables them; no automated or remote recovery recorded (the manual, on-site detail is inferred from the recovery profile)
- Prevention in place
- None recorded
- Detection in place
- Known from onset; the pace of recovery was learned during the event
- S 8
- Sets the duration of the outage carried by FM-02: hours of full outage of a major service is the rubric's 8.
- O 6
- Hold-down is standard behaviour, so it applies every time the thresholds trip: 'occasional'.
- D 8
- No recovery automation or drill is recorded, so the restoration time was learned only after impact.
Corrective action
- Automated router-session recovery and pre-staged remote reboot capability (analyst recommendation) Improvement #5
Who acts — playbook
- Service recovery lead Pre-stage remote reboot and automated session recovery for PE routers so restoration needs no site visitsImprovement #5
- First responder Track the count of down PE sessions against time and report restored percentage to the commander every 30 minutesSRE incident mgmt
- Operations lead Order the PE routers by customer weight and restore the largest populations firstITIL 4
- Service recovery lead Reconnect and reboot routers in turn until the fleet is restored; the record shows 11% at 11:30 and 88% at 13:00ITIL 4
- Communications lead Publish restored percentage and next update time so customers see progress, not silenceITIL 4
On the record at this failure
- Service recovery lead Reconnect and reboot the affected routers by hand because tripped BGP sessions do not self-heal
Evidence
- Contributing factor #4No automatic recovery / manual-only restoration: tripped BGP sessions did not self-heal, so restoration proceeded gradually (11% by 11:30, 88% by 13:00) and the outage ran ~12-13 hours (Wikipedia).
- Metric #5Restoration progress: ~11% by 11:30 AEDT; ~88% by 13:00 AEDT
- Metric #4Outage duration: ~12-13 hours (some media reported up to 14)
- Sequence of events #138 Nov 2023, morning-afternoon — Because tripped BGP sessions do not self-heal, engineers manually reconnected/rebooted affected routers (manual/on-site detail inferred from the recovery profile).
- Technical deep-dive“tripped max-prefix sessions typically do not silently re-establish when the flood subsides”
FM-01 A software upgrade at a North American Singtel exchange makes one router disconnect, and the resulting flood of ~940,000 BGP announcements in an hour reaches Optus unfilteredSingtel international peering boundary to Optus AS4804 9·5·8 360 —
- Function
- Absorb an upstream routing event without passing an abnormal flood into Optus's core
- Effect
- Optus's edge routers receive about 300 times their normal hourly announcement rate, which trips their route limits (FM-02)
- Cause
- No apparent inbound prefix-filtering or route rate-limiting at the peering boundary (inferred from the mechanism, not a verbatim finding); causation reportedly disputed by Singtel
- Prevention in place
- None recorded at the boundary
- Detection in place
- Cloudflare telemetry registered the spike; nothing at the boundary is recorded to have caught it
- S 9
- This is the trigger of a nationwide outage of a foundational telecom service with no workaround for Optus customers: the rubric's 9. The people hazard through 000 is scored in FM-04.
- O 5
- Software upgrades on peering routers are routine, and no boundary guard is recorded, but a flood of this size from an upgrade is not routine: between 'infrequent' and 'occasional'. Held at 5 because the filtering gap is inferred and causation is disputed.
- D 8
- The spike was visible in external telemetry, but no control at the boundary is recorded to have caught it; its first internal effect was the outage, so 'detected after impact'.
Corrective action
- Inbound prefix-filtering and route rate-limiting at the Singtel peering boundary (status: under review; ownership reportedly disputed) Correction of errors #2
- Peering-boundary hygiene: prefix filters, route-count rate limits and AS-path checks at Singtel ingress (analyst recommendation) Improvement #2
Who acts — playbook
- Change owner Add inbound prefix filters and a route-count rate limit on the Singtel ingress toward AS4804 before any exchange upgradeCorrection of errors #2
- First responder Alarm Optus NOC on BGP announcement rate from Singtel peers against the 3,000 per hour baseline, instead of relying on Cloudflare telemetrySRE incident mgmt
- Change owner Shut the affected Singtel peering session or apply a max-prefix cut at ingress when announcements spike far over baselineChange management
- Operations lead Hold all other Singtel router upgrades in the window until the offending node is identifiedChange management
- Service recovery lead Re-establish the peering session only after the filter is in place and the announcement rate is back near baselineITIL 4Improvement #2
On the record at this failure
- Change owner Performs a scheduled software upgrade on a Singtel peering router, the trigger of the BGP flood
Evidence
- Sequence of events #17-8 Nov 2023 (pre-onset) — Scheduled software upgrade performed on a router at a North American node of Singtel's international peering network, the upstream infrastructure Optus's IP core depends on.
- Sequence of events #28 Nov 2023, ~04:05 AEDT — The Singtel exchange upgrade caused one router to disconnect, initiating an abnormal BGP route-advertisement event toward Optus's AS4804.
- Metric #1BGP route-announcement flood: ~940,000 announcements in one hour vs <3,000/hr normal (~300x)
- Contributing factor #3Upstream peering-hygiene gap (inferred from mechanism): a North American Singtel exchange upgrade was allowed to propagate a ~940,000-route BGP event downstream toward AS4804 (normal <3,000/hr) with no apparent upstream prefix-filtering or rate-limiting to contain it (Cloudflare figure via Wikipedia).
- Root cause“inferred from the mechanism, not a verbatim finding”
- Contributing factor #6Disputed / unclear change ownership at the Singtel-Optus boundary: Singtel was reported to have refuted early claims that its upgrade caused the outage (ZDNet, not re-verified this session), indicating unclear accountability and coordination.
FM-02 The same Cisco default threshold trips on ~90 PE routers near-simultaneously and each tears down its BGP sessions, so the protective action isolates the whole IP coreRoute-limit thresholds on Optus's Cisco Provider Edge routers 9·5·8 360 —
- Function
- Protect each router from routing-update overload without cutting customers off the network
- Effect
- Nationwide loss of mobile and fixed service for more than 10 million people and 400,000 businesses; Melbourne trains, hospital phone lines and EFTPOS terminals disrupted
- Cause
- Thresholds left at 'the pre-configured default threshold limits set by Cisco Systems' rather than tuned to Optus's route counts, with hard session teardown as the response
- Prevention in place
- The threshold itself, which prevented CPU/memory exhaustion as designed
- Detection in place
- The routers detected the threshold breach; that detection triggered the teardown
- S 9
- Provider-wide outage of a foundational national telecom service for hours with no workaround: the rubric's 9. The 000 failures are scored separately in FM-04 rather than here.
- O 5
- The default configuration is a standing condition, but it only fires on an abnormal flood: between 'infrequent' and 'occasional'. Scored like FM-01 so the trigger and the amplifier together are not counted as two frequent events.
- D 8
- The only control that saw the flood was the threshold whose trip was the outage; no alerting that would allow action before customers lost service is recorded.
Corrective action
- Tune PE route-limit thresholds off Cisco defaults with graceful warn/restart behaviour (directed by the Bean review / Senate inquiry; status not retrievable) Correction of errors #1
- Operator-tuned limits with soft warning-then-restart behaviour (analyst recommendation) Improvement #1
Who acts — playbook
- Vendor / upstream provider Advise operators in writing that Cisco default route-limit thresholds are not sized to their route counts and must be tunedChange managementLesson #2
- Change owner Set operator-tuned limits with warn-then-restart behaviour on every PE router rather than synchronized hard session teardownChange managementCorrection of errors #1
- First responder Alert the NOC when PE route counts pass a warning level well below the teardown threshold, so staff act before routers isolateSRE incident mgmt
- Incident commander Declare the incident, confirm no cyberattack, and set the first goal as getting the PE fleet back in BGPSRE incident mgmt
- Service recovery lead Clear the flood source first, then reconnect the PE routers in batches so they do not trip again on re-advertisementITIL 4
Evidence
- Sequence of events #48 Nov 2023, ~04:05 AEDT — Optus's Cisco PE routers registered the flood as incoming route updates crossed 'the pre-configured default threshold limits set by Cisco Systems.'
- Sequence of events #68 Nov 2023, ~04:05-04:10 AEDT — 'Approximately 90 edge provider routers disconnected as an automated protective measure against routing update overload' — a synchronized self-isolation across the PE fleet.
- Metric #2Provider Edge routers self-disconnected: ~90 edge/PE routers
- Contributing factor #1Configuration/maintenance lapse on Optus PE routers: they were left on 'the pre-configured default threshold limits set by Cisco Systems' rather than thresholds tuned to Optus's real route counts, so a foreseeable flood tripped a hard fail-safe instead of degrading gracefully (Wikipedia, citing the outage account).
- Contributing factor #2Synchronized fail-safe design flaw: because the identical default limit tripped across ~90 PE routers near-simultaneously, the protective mechanism produced a fleet-wide disconnection cascade rather than isolating a single fault — the 'containment' had no firebreak (Wikipedia).
- Metric #3People affected: >10 million people and 400,000 businesses
- Reference #1 · press“Approximately 90 edge provider routers disconnected as an automated protective measure against routing update overload”
FM-04 Emergency 000 calls fail for affected customers, with no effective fallback during the IP-core lossTriple-Zero (000) emergency calling 10·4·9 360 —
- Function
- Connect emergency calls from Optus customers even when Optus's IP core is down
- Effect
- Customers cannot reach emergency services; the exact number of failed calls is not in the retrievable record; this became the central concern of ACMA and the Senate inquiry
- Cause
- 000 calling depended on the same IP core, with no resilient fallback path recorded
- Prevention in place
- None recorded
- Detection in place
- Through failed calls
- S 10
- Rubric 10, hazard to people: emergency calls failed. No specific harm is recorded in the dossier, but losing access to emergency services is the hazard itself.
- O 4
- Needs the IP core to fail first, which is infrequent; kept low so the single outage is not counted again at full weight.
- D 9
- The failure was found when calls did not connect, the analogue of detection through customer impact.
Corrective action
- Resilient 000 failover independent of the Optus IP core plus welfare-check procedures (regulatory focus; status not retrievable) Correction of errors #3
- 000 failover path independent of the Optus IP core with automated welfare checks (analyst recommendation) Improvement #4
Who acts — playbook
- Authority / investigator Require Triple-Zero calling to stay available when the carrier's IP core is down, for example by camp-on to other networksImprovement #4
- First responder Run a continuous test call to 000 from a probe on the Optus network and page the NOC on the first failureSRE incident mgmt
- Incident commander Notify emergency services and the regulator at once that 000 is failing, so they can run alternate channelsITIL 4
- Communications lead Tell customers to use a landline or another carrier's phone for emergenciesITIL 4
- Service recovery lead Restore the 000 path first among customer services and run a welfare-check process for missed callsCorrection of errors #3
On the record at this failure
- Crisis lead CEO resigns on 20 Nov 2023, twelve days after the outage
- Authority / investigator Government opens a Senate inquiry and the Bean review into the outage
Evidence
- Sequence of events #98 Nov 2023, morning — Emergency Triple-Zero (000) calls failed for affected customers; exact count of failed calls not in retrievable record.
- Metric #10Emergency-services impact: Triple-Zero (000) calls failed (exact count not in retrievable record)
- Contributing factor #5Triple-Zero (000) failover inadequacy: emergency 000 calls failed with no effective resilient fallback during the IP-core loss, later a central regulatory concern of ACMA / the Senate inquiry (Wikipedia).
- Sequence of events #1820 Nov 2023 — Optus CEO Kelly Bayer Rosmarin resigned; a Senate public inquiry and an independent government (Bean) review were established.
FM-05 An upstream upgrade proceeds with no recorded joint staged rollout, blast-radius review or coordinated rollback, and ownership of the change is disputed afterwardsChange management across the Singtel-Optus boundary 7·6·8 336 —
- Function
- Review and stage changes on shared upstream infrastructure for their blast radius on Optus
- Effect
- A change in North America reaches 10 million Australians; accountability is contested after the event
- Cause
- No joint change process recorded between the two companies; Singtel reportedly refuted early causation claims (ZDNet, not re-verified)
- Prevention in place
- None recorded
- Detection in place
- None recorded before the change took effect
- S 7
- A process precursor whose consequence runs through FM-01 and FM-02; scored at 7 so the national outage is not counted a third time at full weight.
- O 6
- Upgrades on shared infrastructure happen routinely and no joint guard is recorded: 'occasional'. Held at 6 because the dossier's evidence for the gap is the outcome and a disputed press report.
- D 8
- No pre-change review is recorded that would have flagged the downstream risk; the gap surfaced through the outage.
Corrective action
- Joint Singtel-Optus staged change management with blast-radius review and coordinated rollback (recommended; not verified) Correction of errors #4
- Joint change management closing the accountability gap at the peering boundary (analyst recommendation) Improvement #3
Who acts — playbook
- Change owner Run Singtel and Optus changes through one joint staged rollout with a blast-radius review and a coordinated rollback planCorrection of errors #4
- Crisis lead Agree in writing who owns a change on shared infrastructure, so accountability is not disputed afterwardsContributing factor #6
- First responder Give the Optus NOC advance notice of every Singtel change window and watch BGP counters through itChange management
- Incident commander Call a joint Singtel and Optus bridge so the upstream change owner can stop and roll back the upgradeSRE incident mgmt
- Change owner Roll back the exchange upgrade on the node that disconnected and confirm announcements are back to normalChange management
On the record at this failure
- Change owner Performs a scheduled software upgrade on a Singtel peering router, the trigger of the BGP flood
Evidence
- Contributing factor #6Disputed / unclear change ownership at the Singtel-Optus boundary: Singtel was reported to have refuted early claims that its upgrade caused the outage (ZDNet, not re-verified this session), indicating unclear accountability and coordination.
- Root cause“Attribution of change ownership was reportedly disputed”
- Sequence of events #17-8 Nov 2023 (pre-onset) — Scheduled software upgrade performed on a router at a North American node of Singtel's international peering network, the upstream infrastructure Optus's IP core depends on.
Scoring rubric and method
Scales adapted from IEC 60812:2018 and AIAG-VDA. RPN = S × O × D. High: S ≥ 9 with O ≥ 4 or D ≥ 7, or RPN ≥ 300. Medium: RPN ≥ 120 or S ≥ 7. Severity overrides the product: 9 × 2 × 9 = 162 would otherwise hide a region-wide outage nothing could catch. Quotes are checked verbatim against this dossier; a revised score needs a published action. RZ analyst assessment, not an operator document.
Severity
| 10 | Hazard to people, or loss of the facility / several regions |
| 9 | Region-wide or provider-wide outage of a foundational service, no workaround |
| 8 | Full outage of a major service for hours |
| 7 | Major degradation of a major service |
| 6 | Partial outage confined to one zone or one service |
| 5 | Customer-visible degradation |
| 4 | Limited customer impact |
| 3 | Internal impact only |
| 2 | Negligible |
| 1 | No effect |
Occurrence
| 10 | Near certain: the cause is present in normal operation |
| 8 | Frequent: routine work exercises the cause |
| 6 | Occasional: a foreseeable slip or condition, weakly guarded |
| 4 | Infrequent: needs an unusual combination |
| 2 | Remote: guarded by design |
| 1 | Eliminated by design |
Detection
| 10 | No control could detect it |
| 9 | Detected only through customer impact |
| 8 | Detected after impact by internal monitoring |
| 6 | Detected at onset, not prevented |
| 4 | Detected before impact with time to act |
| 2 | Automated interlock almost certainly stops it |
| 1 | Certain to be stopped |
Root cause and contributing factors
Full root-cause narrative
Contributing factors by category
- Configuration/maintenance lapse on Optus PE routers: they were left on 'the pre-configured default threshold limits set by Cisco Systems' rather than thresholds tuned to Optus's real route counts, so a foreseeable flood tripped a hard fail-safe instead of degrading gracefully (Wikipedia, citing the outage account).
- Synchronized fail-safe design flaw: because the identical default limit tripped across ~90 PE routers near-simultaneously, the protective mechanism produced a fleet-wide disconnection cascade rather than isolating a single fault — the 'containment' had no firebreak (Wikipedia).
- Upstream peering-hygiene gap (inferred from mechanism): a North American Singtel exchange upgrade was allowed to propagate a ~940,000-route BGP event downstream toward AS4804 (normal <3,000/hr) with no apparent upstream prefix-filtering or rate-limiting to contain it (Cloudflare figure via Wikipedia).
- No automatic recovery / manual-only restoration: tripped BGP sessions did not self-heal, so restoration proceeded gradually (11% by 11:30, 88% by 13:00) and the outage ran ~12-13 hours (Wikipedia).
- Triple-Zero (000) failover inadequacy: emergency 000 calls failed with no effective resilient fallback during the IP-core loss, later a central regulatory concern of ACMA / the Senate inquiry (Wikipedia).
- Disputed / unclear change ownership at the Singtel-Optus boundary: Singtel was reported to have refuted early claims that its upgrade caused the outage (ZDNet, not re-verified this session), indicating unclear accountability and coordination.
Analysis
What actually failed
A scheduled software upgrade on a router at a North American Singtel exchange caused that router to disconnect, generating an abnormal BGP re-advertisement event toward Optus's AS4804 — Cloudflare-cited telemetry recorded over 940,000 announcements in one hour versus a normal baseline below 3,000. Optus's Cisco Provider Edge routers hit 'the pre-configured default threshold limits set by Cisco Systems' and, as designed, tore down their BGP sessions; approximately 90 edge routers disconnected, effectively removing Optus's IP core from the internet. The protective mechanism working correctly was the outage.
Why a protective feature became the disaster
Two latent design lapses turned a foreseeable event into a national outage. The PE fleet ran on Cisco DEFAULT thresholds rather than limits tuned to Optus's real route counts, so a ~300x flood breached a hard fail-safe instead of degrading gracefully. Because the identical default limit tripped across ~90 routers at once, the 'containment' produced a synchronized cascade with no firebreak. Upstream, the Singtel exchange upgrade propagated the route event downstream with no evident prefix-filtering or rate-limiting at the peering boundary. Both are inferences from the confirmed mechanism, not verbatim official findings.
Impact and physical-world cascade
Service loss hit more than 10 million people and 400,000 businesses. Triple-Zero (000) emergency calls failed — the issue that dominated the regulatory response. Melbourne's train network shut down between 05:00 and 06:00 with about 500 services cancelled; hospital phone lines and EFTPOS terminals were disrupted. Restoration was gradual (11% by 11:30, 88% by 13:00 AEDT) over roughly 12-13 hours, consistent with BGP sessions that do not self-heal and require manual re-enablement. Singtel lost over AU$2 billion in value (4.8% share drop) and CEO Kelly Bayer Rosmarin resigned on 20 November 2023.
Evidence quality and open gaps
Only Wikipedia was directly re-fetched this session; the Cloudflare blog (404), ABC, ZDNet, web.archive and Australian government servers (Bean review / ACMA / Senate report) were blocked or timed out. So the Cisco-default-threshold mechanism, ~90 routers, 940,000/3,000 figures, timings, scale, market loss and CEO resignation are confirmed via Wikipedia; competitor-diversion and market-share figures (Motley Fool) and the Singtel causation refutation (ZDNet) remain single-sourced and unverified this session. The verbatim official findings and the exact number of failed 000 calls and Cisco router model/firmware were not retrievable. officialPostmortem is therefore set false: no official/regulatory document was directly obtained with a quotable passage.
Technical deep-dive
Corrective actions and lessons
Correction of errors
| Action | Owner | Status |
|---|---|---|
| Tune all Provider Edge router route-limit thresholds off Cisco defaults to operator-specific values with graceful-degradation (warn/restart) behaviour instead of synchronized hard teardown | Optus Network Engineering | Directed by Bean review / Senate inquiry (verbatim status not retrievable this session) |
| Implement inbound prefix-filtering and route rate-limiting at the Singtel peering boundary to Optus | Singtel / Optus peering teams | Under review (change ownership reportedly disputed; ZDNet, not re-verified) |
| Establish a resilient Triple-Zero (000) failover independent of the Optus IP core plus mandated welfare-check procedures | Optus / ACMA | Regulatory focus of ACMA and Senate inquiry (verbatim status not retrievable this session) |
| Institute joint Singtel-Optus staged change-management with blast-radius review and coordinated rollback | Optus / Singtel change-management | Recommended (not verified this session) |
Lessons learnt
- A safety mechanism that fires fleet-wide simultaneously is not containment but a cascade generator: leaving ~90 PE routers on identical Cisco default thresholds turned a protective feature into the outage itself (Wikipedia).
- Default vendor configuration is a latent hazard — thresholds must be tuned to the operator's real traffic, because a foreseeable ~300x route event tripped ceilings never sized for Optus's network (Cloudflare figure via Wikipedia).
- Blast radius crosses corporate boundaries: an upstream Singtel exchange upgrade in North America took down 10M+ Australians, making peering-boundary filtering and joint change-control essential, not optional (Wikipedia).
- Emergency-services resilience must be decoupled from the commercial IP core: 000 call failure, not the commercial outage alone, drove the regulatory and parliamentary response (Wikipedia).
- Recovery design matters as much as failure design: because tripped BGP sessions do not self-heal, a minutes-long trigger became a ~12-13-hour restoration — automated/remote recovery would have sharply cut the impact (Wikipedia).
Improvements
- DesignReplace Cisco DEFAULT threshold ceilings on all Provider Edge routers with operator-tuned limits sized to real route counts plus headroom, and prefer soft/warning-then-restart behaviour over synchronized hard session-teardown so a flood degrades gracefully instead of self-isolating ~90 routers at once (grounded in the 'pre-configured default threshold limits' failure, Wikipedia).
- MaintenanceEnforce peering-boundary hygiene — inbound prefix-filtering, route-count rate-limiting and AS-path sanity checks at the Singtel ingress — so an upstream exchange upgrade cannot propagate a ~940,000-route event downstream to Optus (Cloudflare figure via Wikipedia).
- Process/Maintenance: Institute joint Singtel-Optus change-management with staged rollout, pre-change blast-radius review and coordinated rollback, closing the disputed accountability gap at the peering boundary (reported Singtel refutation, ZDNet).
- SafetyBuild a resilient Triple-Zero (000) failover path independent of the Optus IP core (e.g. mandated camp-on/roaming to other carriers' networks) plus automated welfare-check procedures, the central concern of ACMA and the Senate inquiry (Wikipedia).
- ProcessAdd automated router-session recovery and pre-staged remote reboot capability so restoration does not depend on gradual manual reconnection that stretched the outage to ~12-13 hours (Wikipedia recovery profile).
References and provenance
- press 2023 Optus outage — Wikipedia (root cause and router mechanism)“Approximately 90 edge provider routers disconnected as an automated protective measure against routing update overload ... exceed the pre-configured default threshold limits set by Cisco Systems.”https://en.wikipedia.org/wiki/2023_Optus_outage
- press 2023 Optus outage — overview (Wikipedia, secondary summary of Optus's stated cause)“changes to routing information from an international peering network ... exceeded preset safety levels on key routers, which disconnected from the Optus IP Core network to protect themselves.”https://en.wikipedia.org/wiki/2023_Optus_outage