Rogers Communications Canada Nationwide Network Outage (July 2022)
Summary
A maintenance change to Rogers' core IP network removed a routing filter, flooding the routers and collapsing the entire national network — taking mobile, internet, 911 emergency calling and Interac payments offline across Canada for roughly 15 hours and affecting about 12 million subscribers.
- Users affected
- ~12 million subscribers nationwide; 911 and Interac payment networks down
- Duration
- 26h 2m — Customer impact 04:58 EDT 8 Jul → full restoration 07:00 EDT 9 Jul (CRTC window).
- Financial
- Regulator-ordered credits + reputational cost; exact figure not consolidated
- Scope
- Sev-1 national network core (multi-hour)
- Site
- Rogers national IP core network · Toronto, Canada
- Services down
- Mobile voice/data, Home internet, 911 emergency calling, Interac debit/e-transfer payments
How the defences failed
National telecom/IP core collapse: mobile, internet, 911, and Interac payments down for ~26 h (CRTC window) for ~12M subscribers — sub-scores ESTIMATED from public impact reporting, pending deep research.
All 10 impact metrics
| Route flood magnitude (one distribution router) | Over 900,000 routes injected vs ~10,000 normally |
| Customers affected | More than 12 million (wireless + wireline) |
| Core router crash time after filter removal | Within minutes |
| Outage window (onset to full restoration) | 04:58 EDT 8 Jul → 07:00 EDT 9 Jul (~26 hours) |
| BGP update spike / peak (external detection) | Spike after 08:15 UTC, peak 08:45 UTC; prefix withdrawal from Rogers ASN |
| Traffic recovery by 09 Jul 08:40 UTC | ~76% of prior-day level at same time |
| Upgrade phase at failure | Phase 6 of a 7-phase core IP-network update |
| Reported deaths (911 unavailable) | At least one reported (avoidability unclear) |
| Wireless/wireline core separation investment | $261 million (CAD) pledged |
| Regulatory MOU deadline | 60 days (mutual assistance / emergency roaming) |
Sequence of events
- TRIGGER During phase six of a seven-phase core IP-network upgrade, Rogers staff remove the Access Control List (ACL) policy filter from the distribution routers' configuration.Change owner
- CASCADE With the filter gone, all possible Internet routes pass into the core; a single distribution router releases over 900,000 route entries into the core routers versus ~10,000 normally.
- CASCADE The route flood exceeds the core routers' processing capacity; the core network routers crash within minutes of the filter's removal.
- DETECTION External BGP telemetry (Cloudflare) records a spike in BGP updates after 08:15 UTC, peaking at 08:45 UTC, with a withdrawal of prefixes from the Rogers ASN — Rogers vanishes from the global routing table.
- DETECTION Rogers is internally blind: the outage severs internal access to systems including the VPN to core network nodes, hampering employees' ability to mobilize a team and identify the issue.Operations lead
- IMPACT Nationwide outage onset — more than 12 million customers lose wireless and wireline services (mobile, home Internet, corporate and institutional).
- IMPACT 9-1-1 access from Rogers mobile phones is unavailable; a Hamilton man reportedly could not call 911 as his sister was dying, though it is unclear whether the death could have been avoided had 911 contact been possible.Customer
- CASCADE Interac is taken offline by the outage, preventing businesses nationwide from accepting debit-card transactions even on other ISPs; some stores temporarily close.
- MITIGATION No suppression analog activates: core routers had no overload protection and the converged architecture had no automatic partition, so nothing contained the flood — a catastrophic loss of all services.
- MITIGATION Recovery cannot be a simple rollback; because the VPN to core nodes is lost, responders must regain management reach, then isolate the flooding distribution routers, purge bad routing state, and rebuild core route tables in stages.Service recovery lead
- RECOVERY Cloudflare observes a first attempt to re-advertise Rogers prefixes as the staged rebuild begins.
- RECOVERY 'Another round of withdraws at around 15:45' — Rogers prefixes are withdrawn again, a recovery setback amid core-network flapping.
- RECOVERY Partial recovery of traffic from the Rogers network, mostly after 00:15 UTC, as services are rebuilt in stages.
- RECOVERY Traffic reaches around 76% of the previous day's level at the same time, though frequent BGP announcements/withdrawals show the core flapping issue is not yet fully resolved.
- RESTORED CRTC dates full restoration; the outage window runs 04:58 EDT 8 July to 07:00 EDT 9 July (approximately 26 hours).Authority / investigator
- RESTORED Minister Champagne sets a 60-day deadline for carriers to agree mutual assistance and emergency roaming; Rogers pledges $261 million to physically separate its wireless and wireline networks.Authority / investigatorCrisis lead
Response by role
What each role did
Roles the sequence of events shows acting; every entry quotes its source line. Select a time to jump to it.
Role by role
Recorded actions / playbook actions per role. A role with 0 recorded actions does not appear in the sources.
No on-call engineer is named; Rogers was blind and Cloudflare saw the withdrawal — Meets the first alarm: on-shift technician or security in a facility, on-call engineer in a service.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
- FM-01Alarm the NOC when a distribution router advertises more routes to the core than a set ceiling, well under 900,000SRE incident mgmt
- FM-04Test out-of-band access to core nodes monthly with the main network deliberately disabledUptime OS
- FM-06Run a test 9-1-1 call from a Rogers handset every few minutes and page on failureSRE incident mgmt
- FM-05Watch BGP announcements and withdrawals during the rebuild and flag flapping as a setbackSRE incident mgmt
- FM-02Alert on core-router CPU and route-table growth rate, not only on link lossSRE incident mgmt
- FM-03Track per-service health (mobile, home internet, 9-1-1 path) separately so a shared-core fault is seen as one eventSRE incident mgmt
- FM-07Monitor the Interac link from the carrier side and alert when transaction volumes dropSRE incident mgmt
No incident commander is named in the record — Owns every decision until formally relieved: site duty manager on scene, or the declared IC of a service incident.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
- FM-01Stop the upgrade on any alarm and order the change owner to restore the filter on the router in questionChange management
- FM-04Switch the response team to the out-of-band path and phones, since the VPN to core nodes is goneSRE incident mgmtLesson #2
- FM-06Tell 9-1-1 centres and the CRTC at once that Rogers mobiles cannot reach 9-1-1ITIL 4
- FM-05Set fixed checkpoints for the rebuild and report restored traffic percentage at eachSRE incident mgmt
- FM-02Declare a national incident and make clearing the flooding distribution routers the first stepSRE incident mgmt
- FM-03Order the unaffected service family to be cut off from the failing core if the split existsSRE incident mgmt
Rogers network staff running phase six of the seven-phase core upgrade — Authored or approved the change, deployment or configuration push that started the event.
On the record
- Remove the ACL policy filter from the distribution routers during phase six of seven, the trigger
Rogers staff remove the Access Control List (ACL) policy filter
Playbook analyst guidance by failure mode, not a record of what happened
- FM-01Lab-test the exact phase-six configuration, including the filter removal, and require a peer sign-off before it reaches productionCorrection of errors #4
- FM-01Apply the change to one distribution router first and watch its route count against the ~10,000 norm before the nextChange management
- FM-04Build a management path on a separate provider and redundant NOC links, independent of the Rogers data networkCorrection of errors #3
- FM-05Write and rehearse a rollback for each phase of the core upgrade, with timingsImprovement #4
- FM-02Configure max-prefix limits and control-plane policing on every core routerCorrection of errors #2
- FM-01Reapply the ACL policy filter on the distribution routers once management access is backChange management
Rogers employees trying to mobilise a team with the VPN to core nodes down — Technical lead who diagnoses and drives the fix; the subject-matter expert at the keyboard or the switchboard.
On the record
- Cannot mobilise a team or find the fault because the VPN to core nodes went down with the network
hampering employees' ability to mobilize a team and identify the issue
Playbook analyst guidance by failure mode, not a record of what happened
- FM-04Mobilise engineers on site to the core nodes when remote access failsNIMS / ICS
- FM-05Re-advertise prefixes in small groups and pause when a group flaps, as the 15:45 UTC withdrawal showedSRE incident mgmt
- FM-02Shut the BGP sessions from the flooding distribution router so the core stops receiving the routesSRE incident mgmt
Rogers responders who rebuilt the core route tables in stages — Restores customer service: failover, workload moves, capacity, backlog drain.
On the record
- Regain management reach, isolate the flooding routers, purge bad routing state and rebuild core tables in stages
responders must regain management reach, then isolate the flooding distribution routers, purge bad routing state, and rebuild core route tables in stages
Playbook analyst guidance by failure mode, not a record of what happened
- FM-04Regain management reach before touching the routers, then roll back the filter changeITIL 4
- FM-06Restore the 9-1-1 call path before general mobile serviceITIL 4
- FM-05Purge bad routing state and rebuild core route tables in stages until traffic is stableITIL 4
- FM-02Reboot the crashed core routers only once the flood source is isolatedITIL 4
- FM-03Restore the services that carry 9-1-1 first, then mobile, then fixed linesITIL 4
- FM-07Restore the Interac connection and confirm debit transactions clear at several merchantsITIL 4
Rogers customer communications — not in the sequence of events — Status page, customer notices, regulators and press; one voice, timed updates.
On the record
No action by this role appears in the sources.
Playbook analyst guidance by failure mode, not a record of what happened
Rogers executive leadership, which pledged $261M for separate networks — Executive owner of business continuity: invokes plans, commits money, speaks to authorities.
On the record
- Pledges $261M to physically separate its wireless and wireline networks
Rogers pledges $261 million to physically separate its wireless and wireline networks
Playbook analyst guidance by failure mode, not a record of what happened
- FM-03Fund and finish the physical split of the wireless and wireline coresCorrection of errors #1
CRTC, with its independent Xona assessment, and Minister Champagne — Regulator, investigator or court that establishes cause and obligations after the event.
On the record
- Dates full restoration at 07:00 EDT on 9 July, about 26 hours after onset
CRTC dates full restoration
- Sets a 60-day deadline for carriers to agree mutual assistance and emergency roaming
Minister Champagne sets a 60-day deadline for carriers to agree mutual assistance and emergency roaming
Playbook analyst guidance by failure mode, not a record of what happened
More than 12 million Rogers customers, Interac users and 9-1-1 callers — The tenant or service user: their own redundancy, backups and continuity plan.
On the record
- A Hamilton man reportedly cannot reach 911 for his dying sister
a Hamilton man reportedly could not call 911 as his sister was dying
Playbook analyst guidance by failure mode, not a record of what happened
- FM-07Let merchants accept cash or offline card mode when Interac failsISO 22301
Failure mode & effects analysis (FMEA)
Rogers' national IP core: the change process for the seven-phase core upgrade, the ACL policy filter on the distribution routers, core-router overload protection, the converged wireless/wireline core, the management path to core nodes, staged recovery, 9-1-1 continuity and the third-party services (Interac) that rode the network. Analysed retrospectively from the CRTC-commissioned independent (Xona) assessment, Rogers' letter to the CRTC as relayed by Wikipedia, and Cloudflare BGP telemetry. The router vendor, model, firmware and age are not public and are not used. Only one action, the $261M wireless/wireline separation, is recorded as a Rogers commitment; the others are CRTC/Xona directions or recommendations, or a ministerial mandate, with completion not recorded, so those modes carry no revised score.
- Caught only after impactD ≥ 8
- 7 of 7
- Actions that cut occurrenceO lowered
- 0
- Actions that cut detectionD lowered
- 0
- Actions that cut severityS lowered
- 1
FM-01 The ACL policy filter is removed from the distribution routers' configuration, letting all possible Internet routes into the coreCore-upgrade change process (phase 6 of 7) 9·6·9 486 —
- Function
- Apply configuration changes to distribution routers without altering what routing state reaches the core
- Effect
- A single distribution router releases over 900,000 routes into the core against about 10,000 normally; the core crashes within minutes and more than 12 million customers lose wireless and wireline service
- Cause
- Change pushed to production without adequate staged lab validation and with no safeguard against the resulting route flood
- Prevention in place
- A phased upgrade plan; no recorded pre-deployment test of this change
- Detection in place
- None inside Rogers before impact; Cloudflare saw a BGP update spike from 08:15 UTC and Rogers prefixes withdrawn at 08:45 UTC
- S 9
- Provider-wide outage of every service a national carrier runs, with no workaround for its customers: the rubric's 9. The hazard to people through 9-1-1 is scored separately in FM-06.
- O 6
- A configuration change in a planned upgrade is routine work, and deleting a filter is a foreseeable slip that nothing in the process guarded: 'occasional'.
- D 9
- No test or check caught the change before it took effect, and Rogers' own access was cut by the outage; the failure is visible in the record through external BGP telemetry and customer loss.
Corrective action
- Strengthen configuration-change control with wide-coverage, rigorous pre-deployment lab testing and staged validation (recommended by CRTC/Xona; completion not recorded) Correction of errors #4
Who acts — playbook
- Change owner Lab-test the exact phase-six configuration, including the filter removal, and require a peer sign-off before it reaches productionCorrection of errors #4
- Change owner Apply the change to one distribution router first and watch its route count against the ~10,000 norm before the nextChange management
- First responder Alarm the NOC when a distribution router advertises more routes to the core than a set ceiling, well under 900,000SRE incident mgmt
- Incident commander Stop the upgrade on any alarm and order the change owner to restore the filter on the router in questionChange management
- Change owner Reapply the ACL policy filter on the distribution routers once management access is backChange management
On the record at this failure
- Change owner Remove the ACL policy filter from the distribution routers during phase six of seven, the trigger
Evidence
- Sequence of events #12022-07-08 pre-onset (approx) — During phase six of a seven-phase core IP-network upgrade, Rogers staff remove the Access Control List (ACL) policy filter from the distribution routers' configuration.
- Sequence of events #2immediately after removal — With the filter gone, all possible Internet routes pass into the core; a single distribution router releases over 900,000 route entries into the core routers versus ~10,000 normally.
- Metric #1Route flood magnitude (one distribution router): Over 900,000 routes injected vs ~10,000 normally
- Contributing factor #1Maintenance/change-control lapse: the ACL policy filter was removed from distribution-router configuration during phase six of a seven-phase core upgrade, with no safeguard against the resulting route flood (CRTC/Xona; Rogers' CRTC letter via Wikipedia).
- Contributing factor #2Inadequate pre-deployment testing: the change reached production without adequate staged lab validation; the CRTC recommended Rogers 'ensure wide coverage and rigor in testing configuration changes' (CRTC/Xona).
- Reference #1 · regulatory“a single distribution router released over 900,000 route data into the core routers”
FM-04 The management VPN to core nodes rides the failed network, so responders lose accessManagement path to core nodes and NOC connectivity 8·6·9 432 —
- Function
- Keep responders able to reach, diagnose and roll back core equipment while the core is down
- Effect
- Employees cannot quickly mobilise a team or identify the issue; recovery cannot be a simple rollback and must first regain management reach
- Cause
- No management path independent of the data network; NOC and critical remote sites lacked redundant connectivity from alternative providers
- Prevention in place
- None recorded
- Detection in place
- Found during the incident
- S 8
- This mode sets how long the outage lasted rather than whether it happened; many hours of full outage of a major service is the rubric's 8.
- O 6
- A standing dependency exercised whenever the core fails, weakly guarded: 'occasional'.
- D 9
- No test of management access under a core failure is recorded; the dependency surfaced when responders were locked out.
Corrective action
- Provision independent out-of-band management and redundant NOC connectivity from alternative providers (directed by CRTC/Xona findings; completion not recorded) Correction of errors #3
Who acts — playbook
- Change owner Build a management path on a separate provider and redundant NOC links, independent of the Rogers data networkCorrection of errors #3
- First responder Test out-of-band access to core nodes monthly with the main network deliberately disabledUptime OS
- Incident commander Switch the response team to the out-of-band path and phones, since the VPN to core nodes is goneSRE incident mgmtLesson #2
- Operations lead Mobilise engineers on site to the core nodes when remote access failsNIMS / ICS
- Service recovery lead Regain management reach before touching the routers, then roll back the filter changeITIL 4
On the record at this failure
- Operations lead Cannot mobilise a team or find the fault because the VPN to core nodes went down with the network
- Service recovery lead Regain management reach, isolate the flooding routers, purge bad routing state and rebuild core tables in stages
Evidence
- Sequence of events #5during onset — Rogers is internally blind: the outage severs internal access to systems including the VPN to core network nodes, hampering employees' ability to mobilize a team and identify the issue.
- Contributing factor #5No independent management path: Rogers lacked redundant NOC/site connectivity from alternative providers, and the outage severed internal access including 'the company's VPN to its core network nodes,' delaying responders (CRTC/Xona; Rogers' CRTC letter via Wikipedia).
- Sequence of events #1008 Jul — Recovery cannot be a simple rollback; because the VPN to core nodes is lost, responders must regain management reach, then isolate the flooding distribution routers, purge bad routing state, and rebuild core route tables in stages.
- Root cause“did not provision its network operation centre and other critical remote infrastructure sites with redundant connectivity from alternative service providers”
FM-06 Rogers mobile users cannot reach 9-1-1, with no inter-carrier emergency-roaming fallback9-1-1 access from Rogers mobiles 10·4·9 360 —
- Function
- Keep emergency calling available when one carrier's core fails
- Effect
- 9-1-1 unavailable from Rogers mobiles; a Hamilton man reportedly could not call 911 as his sister was dying, though whether the death was avoidable is unclear
- Cause
- No inter-carrier emergency-roaming failover for 9-1-1
- Prevention in place
- None recorded
- Detection in place
- Customer impact
- S 10
- Loss of emergency calling is a hazard to people, the rubric's 10, and the dossier records at least one reported death during the outage, with avoidability unclear.
- O 4
- Needs a carrier-wide core failure first, which is infrequent.
- D 9
- No fallback existed to detect or bridge the loss; it was found by people who could not get through.
Corrective action
- Establish and regularly test 9-1-1 emergency-roaming failover across carriers (directed following the outage; completion not recorded) Correction of errors #6
- Agree inter-carrier mutual-assistance and emergency-roaming arrangements within 60 days (ministerial mandate; outcome not recorded) Correction of errors #5
Who acts — playbook
- Authority / investigator Require tested inter-carrier emergency roaming so 9-1-1 calls fall back to another networkCorrection of errors #6
- First responder Run a test 9-1-1 call from a Rogers handset every few minutes and page on failureSRE incident mgmt
- Incident commander Tell 9-1-1 centres and the CRTC at once that Rogers mobiles cannot reach 9-1-1ITIL 4
- Communications lead Tell customers to use a landline or another carrier's phone for emergenciesITIL 4
- Service recovery lead Restore the 9-1-1 call path before general mobile serviceITIL 4
On the record at this failure
Evidence
- Sequence of events #708 Jul, morning — 9-1-1 access from Rogers mobile phones is unavailable; a Hamilton man reportedly could not call 911 as his sister was dying, though it is unclear whether the death could have been avoided had 911 contact been possible.
- Metric #8Reported deaths (911 unavailable): At least one reported (avoidability unclear)
- Contributing factor #6No inter-carrier emergency-roaming failover: Rogers mobile users had no 9-1-1 fallback during the outage, prompting the post-incident emergency-roaming mandate (CRTC/Xona; Champagne undertakings via Wikipedia).
FM-05 Staged rebuild is slow and relapses, with prefixes withdrawn again and the core flappingCore recovery procedure 7·5·9 315 —
- Function
- Rebuild the core route tables and services quickly and stably after a collapse
- Effect
- Re-advertisement attempt at 14:30 UTC, renewed withdrawals around 15:45 UTC, partial traffic mostly after 00:15 UTC, about 76% of prior-day traffic by 08:40 UTC on 9 July; CRTC dates full restoration to 07:00 EDT on 9 July, about 26 hours after onset
- Cause
- No rollback containment or fault isolation for this change; responders had to isolate the flooding routers, purge routing state and rebuild in stages
- Prevention in place
- None recorded
- Detection in place
- Found during recovery
- S 7
- It stretches the outage, but FM-04 already carries the duration at 8, so this mode is scored one step lower to avoid counting the same hours twice at full weight.
- O 5
- Present whenever a core-wide collapse needs rebuilding, with no recorded rehearsed rollback: between 'infrequent' and 'occasional'.
- D 9
- No rehearsal is recorded that would reveal recovery time or flapping before an incident; the setbacks were seen in external BGP telemetry as they happened.
Corrective action
- Staged validation of every core-router change with tested rollback before production rollout (analyst/CRTC recommendation; no status) Improvement #4
Who acts — playbook
- Change owner Write and rehearse a rollback for each phase of the core upgrade, with timingsImprovement #4
- First responder Watch BGP announcements and withdrawals during the rebuild and flag flapping as a setbackSRE incident mgmt
- Operations lead Re-advertise prefixes in small groups and pause when a group flaps, as the 15:45 UTC withdrawal showedSRE incident mgmt
- Incident commander Set fixed checkpoints for the rebuild and report restored traffic percentage at eachSRE incident mgmt
- Service recovery lead Purge bad routing state and rebuild core route tables in stages until traffic is stableITIL 4
Evidence
- Sequence of events #1108 Jul 14:30 UTC — Cloudflare observes a first attempt to re-advertise Rogers prefixes as the staged rebuild begins.
- Sequence of events #1208 Jul ~15:45 UTC — 'Another round of withdraws at around 15:45' — Rogers prefixes are withdrawn again, a recovery setback amid core-network flapping.
- Sequence of events #1409 Jul 08:40 UTC — Traffic reaches around 76% of the previous day's level at the same time, though frequent BGP announcements/withdrawals show the core flapping issue is not yet fully resolved.
- Metric #4Outage window (onset to full restoration): 04:58 EDT 8 Jul → 07:00 EDT 9 Jul (~26 hours)
- Reference #2 · vendor-status“at 08:45 there was a withdrawal of prefixes from Rogers ASN”
FM-02 Core routers accept the route flood and crash within minutesCore router control plane (overload protection) 9·4·8 288 —
- Function
- Reject or limit an excessive route injection instead of processing it to failure
- Effect
- The core control plane collapses and Rogers' ASN disappears from the global routing table
- Cause
- Core routers 'were not configured with such overload protection mechanisms' (max-prefix, route limits, control-plane policing)
- Prevention in place
- None: no overload protection configured
- Detection in place
- None recorded before the crash
- S 9
- This is the step that turned a filter deletion into a national collapse, so it carries the same severity as FM-01.
- O 4
- The missing protection is a standing condition, but it only fails when an unbounded route injection arrives, which needs a change like FM-01 first: 'infrequent'. Kept below FM-01 so the event is not counted twice at full weight.
- D 8
- Nothing recorded flagged the route-table growth before the crash 'within minutes'; it was seen after impact.
Corrective action
- Implement router overload protection (max-prefix, route limits, control-plane policing) on core routers (directed by CRTC/Xona findings; completion not recorded) Correction of errors #2
Who acts — playbook
- Change owner Configure max-prefix limits and control-plane policing on every core routerCorrection of errors #2
- First responder Alert on core-router CPU and route-table growth rate, not only on link lossSRE incident mgmt
- Operations lead Shut the BGP sessions from the flooding distribution router so the core stops receiving the routesSRE incident mgmt
- Incident commander Declare a national incident and make clearing the flooding distribution routers the first stepSRE incident mgmt
- Service recovery lead Reboot the crashed core routers only once the flood source is isolatedITIL 4
Evidence
- Contributing factor #3No overload protection on core routers: 'the Rogers core network routers were not configured with such overload protection mechanisms,' so >900,000 routes (vs ~10,000 normal) crashed the core within minutes (CRTC/Xona).
- Sequence of events #3within minutes of removal — The route flood exceeds the core routers' processing capacity; the core network routers crash within minutes of the filter's removal.
- Metric #3Core router crash time after filter removal: Within minutes
- Root cause“the Rogers core network routers were not configured with such overload protection mechanisms”
FM-03 Wireless and wireline share one IP core, so a single core failure takes down every service togetherConverged wireless/wireline IP core 9·4·8 288 256
- Function
- Contain a core fault to one service family
- Effect
- Mobile voice and data, home Internet, enterprise services and 9-1-1 from Rogers mobiles drop simultaneously: 'a catastrophic loss of all services'
- Cause
- No partition between wireless and wireline in the core architecture
- Prevention in place
- None recorded
- Detection in place
- None recorded; the shared fate showed itself at onset through loss of all services
- S 9
- Loss of all of a national carrier's services at once is the rubric's 9.
- O 4
- Needs a core-wide fault first, which is infrequent.
- D 8
- No control contained or flagged the shared fate; it was learned through the outage itself.
Corrective action
- Physically separate wireless and wireline core networks ($261M pledge) so one fault cannot collapse all services Correction of errors #1
- Physically separate the wireless and wireline core networks Improvement #1
After action: S8 · O4 · D8 → RPN 256. With separate cores, a fault of this kind would take down one service family rather than both (S 9→8; still a full outage of a major service for hours). O and D are unchanged because separation does not stop the triggering fault or detect it. Rogers' pledge is recorded as committed post-incident, not as completed, so the reduction is a claim about the action, not a confirmed outcome.
Who acts — playbook
- Crisis lead Fund and finish the physical split of the wireless and wireline coresCorrection of errors #1
- First responder Track per-service health (mobile, home internet, 9-1-1 path) separately so a shared-core fault is seen as one eventSRE incident mgmt
- Incident commander Order the unaffected service family to be cut off from the failing core if the split existsSRE incident mgmt
- Communications lead Say at once that mobile, internet and 9-1-1 are all down, rather than service by serviceITIL 4
- Service recovery lead Restore the services that carry 9-1-1 first, then mobile, then fixed linesITIL 4
Evidence
- Contributing factor #4Converged single-core architecture: wireless and wireline shared one IP core, so the outage 'resulted in a catastrophic loss of all services' — one change felled mobile, wireline, and 9-1-1 together (CRTC/Xona).
- Sequence of events #604:58 EDT — Nationwide outage onset — more than 12 million customers lose wireless and wireline services (mobile, home Internet, corporate and institutional).
- Sequence of events #908 Jul — No suppression analog activates: core routers had no overload protection and the converged architecture had no automatic partition, so nothing contained the flood — a catastrophic loss of all services.
- Metric #2Customers affected: More than 12 million (wireless + wireline)
FM-07 Interac is taken offline by the Rogers outageThird-party critical services carried on Rogers (Interac) 8·4·9 288 —
- Function
- Keep services used by customers of other carriers running when one carrier fails
- Effect
- Businesses nationwide cannot accept debit-card transactions, even on other ISPs; some stores temporarily close
- Cause
- Interac depended on the Rogers network
- Prevention in place
- None recorded
- Detection in place
- Customer impact
- S 8
- Full outage of a national payment service for hours, reaching people who were not Rogers customers: the rubric's 8.
- O 4
- Needs the Rogers core to fail first, which is infrequent.
- D 9
- Seen when transactions failed at the point of sale.
Corrective action
- None published — residual risk.
Who acts — playbook
- Authority / investigator Require payment networks like Interac to hold a second carrier pathLesson #5
- Customer Let merchants accept cash or offline card mode when Interac failsISO 22301
- First responder Monitor the Interac link from the carrier side and alert when transaction volumes dropSRE incident mgmt
- Communications lead Tell merchants and Interac of the outage so they can switch to alternate processingITIL 4
- Service recovery lead Restore the Interac connection and confirm debit transactions clear at several merchantsITIL 4
Evidence
- Sequence of events #808 Jul, daytime — Interac is taken offline by the outage, preventing businesses nationwide from accepting debit-card transactions even on other ISPs; some stores temporarily close.
- Technical deep-dive“mobile, home Internet, enterprise, 9-1-1, and Interac dropped simultaneously”
Scoring rubric and method
Scales adapted from IEC 60812:2018 and AIAG-VDA. RPN = S × O × D. High: S ≥ 9 with O ≥ 4 or D ≥ 7, or RPN ≥ 300. Medium: RPN ≥ 120 or S ≥ 7. Severity overrides the product: 9 × 2 × 9 = 162 would otherwise hide a region-wide outage nothing could catch. Quotes are checked verbatim against this dossier; a revised score needs a published action. RZ analyst assessment, not an operator document.
Severity
| 10 | Hazard to people, or loss of the facility / several regions |
| 9 | Region-wide or provider-wide outage of a foundational service, no workaround |
| 8 | Full outage of a major service for hours |
| 7 | Major degradation of a major service |
| 6 | Partial outage confined to one zone or one service |
| 5 | Customer-visible degradation |
| 4 | Limited customer impact |
| 3 | Internal impact only |
| 2 | Negligible |
| 1 | No effect |
Occurrence
| 10 | Near certain: the cause is present in normal operation |
| 8 | Frequent: routine work exercises the cause |
| 6 | Occasional: a foreseeable slip or condition, weakly guarded |
| 4 | Infrequent: needs an unusual combination |
| 2 | Remote: guarded by design |
| 1 | Eliminated by design |
Detection
| 10 | No control could detect it |
| 9 | Detected only through customer impact |
| 8 | Detected after impact by internal monitoring |
| 6 | Detected at onset, not prevented |
| 4 | Detected before impact with time to act |
| 2 | Automated interlock almost certainly stops it |
| 1 | Certain to be stopped |
Root cause and contributing factors
Full root-cause narrative
Contributing factors by category
- Maintenance/change-control lapse: the ACL policy filter was removed from distribution-router configuration during phase six of a seven-phase core upgrade, with no safeguard against the resulting route flood (CRTC/Xona; Rogers' CRTC letter via Wikipedia).
- Inadequate pre-deployment testing: the change reached production without adequate staged lab validation; the CRTC recommended Rogers 'ensure wide coverage and rigor in testing configuration changes' (CRTC/Xona).
- No overload protection on core routers: 'the Rogers core network routers were not configured with such overload protection mechanisms,' so >900,000 routes (vs ~10,000 normal) crashed the core within minutes (CRTC/Xona).
- Converged single-core architecture: wireless and wireline shared one IP core, so the outage 'resulted in a catastrophic loss of all services' — one change felled mobile, wireline, and 9-1-1 together (CRTC/Xona).
- No independent management path: Rogers lacked redundant NOC/site connectivity from alternative providers, and the outage severed internal access including 'the company's VPN to its core network nodes,' delaying responders (CRTC/Xona; Rogers' CRTC letter via Wikipedia).
- No inter-carrier emergency-roaming failover: Rogers mobile users had no 9-1-1 fallback during the outage, prompting the post-incident emergency-roaming mandate (CRTC/Xona; Champagne undertakings via Wikipedia).
Analysis
No fire — a congestive control-plane collapse
This was not a physical or thermal event; it was a routing/control-plane failure. The 'ignition' analog is the deletion of the ACL policy filter on the distribution routers, and the 'fuel' is the uncontrolled injection of routing state into the core. With the filter present, roughly 10,000 routes reached the core; with it gone, a single distribution router pushed 'over 900,000 route data into the core routers,' exceeding processing capacity and crashing the core 'within minutes.' The mechanism is specific and vendor-agnostic: route-table saturation of the control plane, not any hardware defect.
Latent causes: convergence, no overload protection, no independent management
Three latent conditions turned a foreseeable misconfiguration into a national outage. Convergence put wireless and wireline on one IP core, so the CRTC found the fault 'resulted in a catastrophic loss of all services' with no partition to contain it. Core routers had no overload protection ('were not configured with such overload protection mechanisms'), so nothing rejected the flood. And the management path was not independent — Rogers lacked redundant NOC connectivity and lost 'the company's VPN to its core network nodes,' blinding responders and preventing a quick rollback.
External signature and staged recovery
Cloudflare's BGP telemetry provides an independent, timestamped view: a spike in BGP updates 'after 08:15, reaching its peak at 08:45,' then 'a withdrawal of prefixes from Rogers ASN' (UTC) — Rogers vanishing from the global table. Recovery was halting: a re-advertisement attempt at 14:30 UTC, 'another round of withdraws at around 15:45,' partial traffic 'mostly after 00:15 UTC,' and about 76% of prior-day traffic by 08:40 UTC on 9 July, with continued flapping. This matches the CRTC's ~26-hour window (04:58 EDT 8 Jul to 07:00 EDT 9 Jul) and the need to isolate routers, purge state, and rebuild in stages.
Systemic impact and regulatory response
Because critical services rode Rogers' single core, the blast radius exceeded its own subscribers: more than 12 million customers lost service, Interac debit went offline 'nationwide,' and 9-1-1 was unavailable from Rogers mobile — with a reported Hamilton death whose avoidability is unclear. The response was structural: Rogers pledged $261 million to physically separate wireless and wireline, and Minister Champagne gave carriers 60 days to agree mutual assistance and emergency roaming, with the CRTC/Xona assessment recommending overload protection, independent management, and rigorous change testing.
Disclosed gaps
The router vendor, model, firmware version, and hardware age are not established by any public source and are recorded as unknown rather than inferred. The exact wall-clock time of the ACL removal is not published; it is bounded only as shortly before the 04:58 EDT onset and consistent with Cloudflare's ~08:15-08:45 UTC BGP activity. The 'substantial restoration within ~15-19 hours' figure from the source draft is unsupported and was removed; the defensible measure is the ~26-hour outage window and the 76%-by-08:40-UTC recovery point.
Technical deep-dive
Corrective actions and lessons
Correction of errors
| Action | Owner | Status |
|---|---|---|
| Physically separate wireless and wireline core networks ($261M pledge) so one fault cannot collapse all services | Rogers Communications (network engineering) | Committed (post-incident) |
| Implement router overload protection (max-prefix / route limits / control-plane policing) on core routers | Rogers Communications | Directed by CRTC/Xona findings |
| Provision independent/out-of-band management and redundant NOC connectivity from alternative providers | Rogers Communications | Directed by CRTC/Xona findings |
| Strengthen configuration-change control with wide-coverage, rigorous pre-deployment lab testing and staged validation | Rogers Communications (change management), per CRTC recommendation | Recommended by CRTC/Xona |
| Agree inter-carrier mutual-assistance and emergency-roaming arrangements within 60 days | All Canadian telecom providers, mandated by Minister Champagne / ISED | Mandated (60-day deadline) |
| Establish and regularly test 9-1-1 emergency-roaming failover across carriers | Canadian carriers / CRTC oversight | Directed following the outage |
Lessons learnt
- A single removed guardrail in a converged core is a national single point of failure: removing one ACL filter injected over 900,000 routes and crashed the core within minutes, taking mobile, wireline, 9-1-1, and Interac down together (CRTC/Xona).
- The management plane must survive the data plane it manages: because the VPN to core nodes rode the failed network, Rogers was blinded and could not quickly mobilize or roll back — independent, out-of-band access is not optional (CRTC/Xona; Rogers' CRTC letter).
- Overload protection must be assumed-on, not assumed-safe: core routers with no route-limit safeguard forwarded themselves to death when a foreseeable misconfiguration occurred (CRTC/Xona).
- Change control needs rigorous staged lab validation and tested rollback: pushing an unfiltered configuration into production during phase six of a live seven-phase upgrade converted a routine change into a ~26-hour national outage (CRTC/Xona; Rogers' CRTC letter).
- Critical-infrastructure dependencies are systemic: Interac and 9-1-1 riding on one carrier pushed the failure into nationwide debit payments and emergency calling, well beyond Rogers' own subscribers (Wikipedia).
- Vendor detail can be a documented gap: the failed routers' make, model, firmware, and age were never publicly disclosed, so this analysis records them as unknown rather than inventing them (CRTC/Xona; public filings).
Improvements
- DesignPhysically separate the wireless and wireline core networks so a single fault cannot collapse all services simultaneously — Rogers pledged $261 million toward this separation (Wikipedia; CRTC/Xona rationale).
- DesignImplement router overload-protection mechanisms (max-prefix / route limits / control-plane policing) on core routers so a route flood is rejected rather than allowed to crash the control plane (CRTC/Xona).
- DesignProvide a management path physically independent of the data network, plus redundant NOC/site connectivity from alternative service providers, so responders retain access even when the core fails (CRTC/Xona).
- MaintenanceStrengthen configuration-change control with rigorous, wide-coverage pre-deployment lab testing and staged validation of every core-router change, with tested rollback before production rollout (CRTC/Xona).
- ProcessEstablish an inter-carrier framework for mutual assistance, emergency roaming for rivals' affected customers, and coordinated public communication, on the 60-day deadline set by Minister Champagne (Wikipedia; CRTC/Xona).
- SafetyGuarantee 9-1-1 continuity via inter-operator emergency-roaming failover, tested regularly, so mobile emergency calling survives a single carrier's core outage (CRTC/Xona; Wikipedia).
References and provenance
- regulatory CRTC — Independent (Xona) assessment of the July 2022 Rogers outage“When this policy filter was removed, a single distribution router released over 900,000 route data into the core routers.”https://crtc.gc.ca/eng/publications/reports/xona2024.htm
- vendor-status Cloudflare — Cloudflare's view of the Rogers Communications outage in Canada“there was a clear spike in BGP (Border Gateway Protocol) updates after 08:15, reaching its peak at 08:45 ... at 08:45 there was a withdrawal of prefixes from Rogers ASN.”https://blog.cloudflare.com/cloudflares-view-of-the-rogers-communications-outage-in-canada/
- press Wikipedia — 2022 Rogers Communications outage (aggregating Rogers' CRTC letter, CBC, government response)“the deletion of a routing filter on its distribution routers caused all possible routes to the internet to pass through the routers, exceeding the capacity of the routers on its core network ... during the sixth phase in a seven-phase update.”https://en.wikipedia.org/wiki/2022_Rogers_Communications_outage
Quotes are short, attributed, and for provenance only; the analysis is original. Last verified 2026-08-02 (seed — pending deep research).