Liquid Cooling · CDU Toolkit

Coolant Distribution Unit toolkit

Everything for selecting, deploying, operating, comparing and sizing liquid-cooling CDUs in AI/HPC data centers — five linked resources, from a verified-spec selection guide to an interactive mini-BMS cockpit and a validated sizing calculator. Pick a tool below.

DC Solutions → CDU Toolkit
01 · Select

CDU Selection & Deployment Guide

Compare in-row, in-rack, sidecar, L2L vs L2A and 2-phase CDUs with verified vendor specs and manual links, the flow/ΔT sizing math, installation requirements, a documentation hub, and an FAQ.

9-col deep tablessizing mathverified links
Open the guide
02 · Operate

Install, Inspection & Maintenance Checklist

Operational parameter bands, water-quality acceptance criteria (ASHRAE W-classes, OCP limits), the numeric commissioning procedure, a symptom→cause→action table, PM cadences, and a printable service-record form.

water qualitycommissioningprintable form
Open the checklist
📡 03 · Visualise

CDU Mini-BMS

An interactive cockpit per CDU type: datahall installation layout, a full ISA P&ID schematic, and live simulated parameters with sparkline trends — inject a fault (leak, pump-fail, clog…) and watch the controls respond.

animated P&IDlive paramsfault scenarios
Open the cockpit
05 · Calculate

Sizing & Thermohydraulic Calculator

Size a CDU from first principles — secondary flow, pipe velocity, pressure drop (Darcy-Weisbach), heat-exchanger approach (ε-NTU), NPSH margin, dew-point reset and pump N+1 power — computed live by a validated engine with basis chips and band checks.

validated engineε-NTU + Darcybasis chips
Open the calculator
04 · Compare

Deep Comparison — All Aspects

Source-tagged comparison across worldwide common field issues, control systems & BMS/DCIM integration, after-sales & warranty per vendor, and TCO & maintenance burden by type — plus a 10-vendor capability matrix.

field issuescontrol + TCOvendor matrix
Open the comparison
Maintenance intelligence — connect the toolkit to the FMECA knowledge base & spares engine
What is a CDU? A Coolant Distribution Unit hydraulically decouples the facility water loop from the chip-side technology cooling loop and regulates flow, temperature and pressure to direct-to-chip cold plates. This toolkit is an independent, educational reference built from published vendor datasheets and standards (ASHRAE TC 9.9, OCP, DMTF Redfish) — every figure is source-tagged, and links are validated. Not procurement, safety, or engineering advice.